Measure initial web width

Measure the unstrained film at an agreed sample location and record the width across the web, sample and roll ID, point in the roll and edge condition. Use that measured initial width as the reference for any percent change. Notes on edge damage or wrinkles can help explain later geometric differences.

Observe applied width

Record the film width at a point that represents the approved wrapping program. Use a safely accessible, calibrated view or a sample measured during an authorized stop under the equipment procedure. Clearly identify whether the width was observed under application tension or after the film relaxed, as the observations describe different states.

Record the point in the cycle, program, load geometry and the location of the measurement. Check coverage and band edges on the finished load, especially around corners and height transitions.

Calculate coverage loss

Change relative to the starting web equals (initial width − applied width) ÷ initial width × 100%. For an illustrative initial width of 500 mm and an applied width of 450 mm, the span is 50 mm smaller, a 10% decrease.

The calculation gives the change in film width. For a coverage decision, measure actual overlap and exposed areas where the successive passes meet on the package.

Adjust overlap with evidence

  1. Mark any thin coverage or gaps by load face and height and record the actual overlap nearby.
  2. Have qualified personnel review the relevant carriage speed or manual wrap path under the site’s equipment procedure.
  3. Repeat the defined trial, then compare overlap, film used and the condition of the wrapped load after the agreed interval.

Keep the working stretch record with the width comparison so reviewers can reproduce the trial.